Full HFFS electronic retrofit: Omron to Rockwell, OEE from 68% to 96%

Food · FMCG · Latin America · end user

Challenge: horizontal packaging machines (HFFS) at a food industry leader with obsolete Omron electronics and a mixed machine fleet. We acted as strategic integrator between the customer and the OEMs, from conceptual engineering to commissioning.

Before
  • PLC Omron CJ1M
  • HMI Proface
  • Yaskawa servo drives
  • Yokogawa flowmeters
  • EZ5N temperature control
  • DeviceNet
After
  • Rockwell CompactLogix 5380
  • PanelView Plus 7 Performance
  • Kinetix 5500 / 5700 servo drives
  • Endress+Hauser mass flowmeters
  • EJ1N temperature control
  • EtherNet/IP
  • OEE from 68% to 96% after the retrofit
  • Standard architecture for multiple lines and machines
  • Coordination with OEMs to adapt interfaces
  • Complete rewiring to improve safety
  • Software improvements to raise OEE
  • No obsolete electronics and spares available in the region